Background
- Primarily used in prehospital setting by EMT's to secure an airway
Indications
- Unresponsive patients with out gag reflex
- Apneic patient being ventilated with BVM
Contraindications
- Conscious patients
- Intact gag reflex
Procedure
Application
- Size OPA from earlobe to mouth
- Open patients mouth and insert OPA with the tip towards the roof of the mouth
- Rotate airway 180° and insert until it is fully inserted
Removal
- Pull out the OPA