High-output heart failure from AV fistula: Difference between revisions
| Line 24: | Line 24: | ||
==Sources== | ==Sources== | ||
<references/> | <references/> | ||
[[Category:Nephro]] | |||
Revision as of 06:27, 12 December 2014
Background
- Occurs when >20% of cardiac output is diverted through the access
Clinical Features
- Branham sign (drop in HR after temporary access occlusion) is diagnostic
Differential Diagnosis
AV Fistula Complications
- Clotting of AV fistula
- Infection of AV fistula
- Hemorrhage of AV fistula
- Vascular insufficiency from AV fistula
- AV fistula aneurysm/pseudoaneurysm
- High-output heart failure from AV fistula
Workup
- Doppler US can accurately measure access flow rate and establish the diagnosis
Management
- Surgical banding of the access
Disposition
- Admit
