Needle thoracostomy: Difference between revisions

No edit summary
Line 9: Line 9:


==Procedure==
==Procedure==
*Insert 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
*Insert 5 cm 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
**Evidence suggests lowest failure rate of needle decompression is at the 4th/5th rib space along the anterior axillary line <ref>Laan DV et al. Chest Wall Thickness and Decompression Failure: A systematic Review and Meta-Analysis Coparing Anatomic Locations in Needle Thoracostomy. Injury 2015 [Epub Ahead of Print]. PMID: 26724173</ref>
*Advance needle until air is aspirated to syringe
*Advance needle until air is aspirated to syringe
*Withdraw needle
*Withdraw needle

Revision as of 22:32, 25 November 2020

Indications

Equipment Needed

  • 14 to 16 gauge IV needle/catheter
  • 5 or 10mL syringe

Procedure

  • Insert 5 cm 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
    • Evidence suggests lowest failure rate of needle decompression is at the 4th/5th rib space along the anterior axillary line [1]
  • Advance needle until air is aspirated to syringe
  • Withdraw needle
  • Leave angiocatheter open to air
  • Immediate rush of air out of chest = tension pneumothorax
  • Follow immediately with standard thoracostomy tube

Complications

See Also

External Links

References

  • Roberts, 179
  • Wolfson, 82, 129
  1. Laan DV et al. Chest Wall Thickness and Decompression Failure: A systematic Review and Meta-Analysis Coparing Anatomic Locations in Needle Thoracostomy. Injury 2015 [Epub Ahead of Print]. PMID: 26724173