Weaning mechanical ventilation: Difference between revisions
ClaireLewis (talk | contribs) |
ClaireLewis (talk | contribs) |
||
| Line 9: | Line 9: | ||
==Greater Predictive Value== | ==Greater Predictive Value== | ||
*Max | *Max inspiratory pressure greater -90cmH2O female, -120cmH2O male, weaning threshold -25 cm h2o | ||
*RSBI: rate/tidal volume < 100 min/L. | *RSBI: rate/tidal volume < 100 min/L. | ||
Revision as of 01:40, 13 July 2016
Weaning Paramater
- PaO2/FiO2 >200
- Tidal volume 5cc/kg
- RR <20
- Vital capacity 10cc/kg
- Minute ventilation. <10L/min
- FiO2 < 0.4 with pO2 > 60 and PEEP < 8
- SBP > 90 without pressors
Greater Predictive Value
- Max inspiratory pressure greater -90cmH2O female, -120cmH2O male, weaning threshold -25 cm h2o
- RSBI: rate/tidal volume < 100 min/L.
Failure to Wean
FAIL TO WEAN [1]
- Fluid overload
- Airway resistance (small ETT, mucous plug, etc.)
- Infection
- Lying down (elevate HOB)
- Thyroid, Toxicity (meds)
- Oxygenation insufficient
- Wheezing (nebs for asthma/COPD)
- Electrolyte abnl (to include Mag and Phos), Eating (nutrition)
- Anti-inflammatories (steroids in asthma/COPD)
- Neuromuscular disease, Neuro status compromised
See Also
Mechanical Ventilation Pages
- Noninvasive ventilation
- Intubation
- Mechanical ventilation (main)
- Miscellaneous
References
- ↑ UIC ICU Guidebook. Mechanical Ventilation - Weaning/Extubation. 2013. http://chicago.medicine.uic.edu/UserFiles/Servers/Server_442934/Image/1.1/residentguides/final/icuguidebook.pdf