Weaning mechanical ventilation: Difference between revisions
| Line 15: | Line 15: | ||
*[[Ventilation (Settings)]] | *[[Ventilation (Settings)]] | ||
*[[Ventilation (Non-Invasive)]] | *[[Ventilation (Non-Invasive)]] | ||
*[[Ventilation ( | *[[Ventilation (Strategies)]] | ||
[[Category:Airway/Resus]] | [[Category:Airway/Resus]] | ||
[[Category:Pulm]] | [[Category:Pulm]] | ||
Revision as of 21:25, 22 July 2011
Weaning Paramater
- PaO2/FiO2 >200
- Tidal volume 5cc/kg
- RR <40
- Vital cap 10cc/kg
- Min vent. <10L/min
greater predictive value
- max inspir. pressure greater -90cmH2O female
- -120 male threshold -25 cm h2o
- RSBI: rate/tidal volume < 100 min/L.
