DVT ultrasound: Difference between revisions
| Line 26: | Line 26: | ||
###Knee flexed 10–30 degree | ###Knee flexed 10–30 degree | ||
###Reverse trendelenberg | ###Reverse trendelenberg | ||
## | ##12cm superior, to 5cm inferior to the popliteal crease | ||
###Vein usually superficial to artery | ###Vein usually superficial to artery | ||
Revision as of 21:07, 10 December 2011
Anatomy
- Significant risk of PE:
- Common femoral vein
- (Superficial) femoral vein
- (Superficial) femoral vein is part of the deep system, not the superficial system as the name suggests!
- Popliteal veins
Technique
- Transducer
- Linear array vascular probe 6–10 MHz
- 6–8cm width ideal (for larger patients, consider abdominal probe)
- Compression
- Compress vein with transducer (probe transverse to vein)
- Touching of anterior and posterior walls = normal
- No touching with pressures sufficient to deform the artery = likely DVT
- Common Femoral Vein
- Patient positioning
- Reverse trendelenberg or semi-sitting with 30 degrees of hip flexion
- Mild external rotation (30 degrees) hip
- 10cm distal to the inguinal crease
- Apply compression every centimeter
- Continue distal to 1-2cm beyond bifurcation of the common femoral vein (into superficial and deep branches)
- Patient positioning
- Popliteal vein
- Patient positioning
- Prone, decubitus position, or seated on edge of gurney
- Knee flexed 10–30 degree
- Reverse trendelenberg
- 12cm superior, to 5cm inferior to the popliteal crease
- Vein usually superficial to artery
- Patient positioning