Weaning mechanical ventilation: Difference between revisions
No edit summary |
Neil.m.young (talk | contribs) (format) |
||
| Line 6: | Line 6: | ||
# Min vent. <10L/min | # Min vent. <10L/min | ||
== | ==Greater Predictive Value== | ||
# | #Max inspir. pressure greater -90cmH2O female, -120cmH2O male, threshold -25 cm h2o | ||
#RSBI: rate/tidal volume < 100 min/L. | #RSBI: rate/tidal volume < 100 min/L. | ||
Revision as of 03:16, 17 April 2015
Weaning Paramater
- PaO2/FiO2 >200
- Tidal volume 5cc/kg
- RR <40
- Vital cap 10cc/kg
- Min vent. <10L/min
Greater Predictive Value
- Max inspir. pressure greater -90cmH2O female, -120cmH2O male, threshold -25 cm h2o
- RSBI: rate/tidal volume < 100 min/L.
Failure to Wean
- FAIL TO WEAN [1]
- Fluid overload
- Airway resistance (small ETT, mucous plug, etc.)
- Infection
- Lying down (elevate HOB)
- Thyroid, Toxicity (meds)
- Oxygenation insufficient
- Wheezing (nebs for asthma/COPD)
- Electrolyte abnl, Eating (nutrition)
- Anti-inflammatories (steroids in asthma/COPD)
- Neuromuscular disease, Neuro status compromised
References