Bladder lavage: Difference between revisions
Neil.m.young (talk | contribs) (Text replacement - "# " to "#") |
(Text replacement - "temp " to "temperature ") |
||
| Line 10: | Line 10: | ||
==Procedure== | ==Procedure== | ||
#Insert | #Insert temperature sensing foley | ||
#Instill 100-200cc warmed fluids | #Instill 100-200cc warmed fluids | ||
#Clamp Foley and wait for foley | #Clamp Foley and wait for foley temperature probe to begin to equilibrate 2-3 degrees celsius | ||
#Drain bladder and repeat | #Drain bladder and repeat | ||
Revision as of 08:28, 1 August 2016
Overview
Indications
- Use if large volumes (>10L) of warmed fluids are not available
- For severe or profound hypothermia
Contraindications
Equipment Needed
Procedure
- Insert temperature sensing foley
- Instill 100-200cc warmed fluids
- Clamp Foley and wait for foley temperature probe to begin to equilibrate 2-3 degrees celsius
- Drain bladder and repeat