Weaning Paramater

  1. PaO2/FiO2 >200
  2. Tidal volume 5cc/kg
  3. RR <40
  4. Vital cap 10cc/kg
  5. Min vent. <10L/min

greater predictive value

  1. max inspir. pressure greater -90cmH2O female
  2. -120 male threshold -25 cm h2o
  3. RSBI: rate/tidal volume < 100 min/L.

Failure to Wean

  • FAIL TO WEAN [1]
    • Fluid overload
    • Airway resistance (small ETT, mucous plug, etc.)
    • Infection
    • Lying down (elevate HOB)
    • Thyroid, Toxicity (meds)
    • Oxygenation insufficient
    • Wheezing (nebs for asthma/COPD)
    • Electrolyte abnl, Eating (nutrition)
    • Anti-inflammatories (steroids in asthma/COPD)
    • Neuromuscular disease, Neuro status compromised

References