Twiddler's syndrome
Background
- Implantable devices with attached wires traveling remotely are at risk.
- Device moves within subcutaneous pocket pulling wires back to device with intentional or unintentional movements.
- Wires dislodged from intended location in myocardium.
Clinical Features
- Pacemaker placed with poor function.
- Can present with syncope from lack of pacemaker function.[1]
- Can present with symptoms related to stimulation of other structures (diaphragm, brachial plexus) as wires migrate from expected position.
Differential Diagnosis
- Lead separation
- Lead dislodgment
- Lead infection
Diagnosis
- CXR to evaluate the lead location
Management
- Cardiologist for device/lead placement
Disposition
- Admit for device revision