Difference between revisions of "Defibrillation"

(References)
 
(5 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
''See [[critical care quick reference]] for defibrillation settings (joules) by weight.''
 
''See [[critical care quick reference]] for defibrillation settings (joules) by weight.''
 +
==Background==
 +
*Unsynchronized shock
  
 
{{Defibrillation and cardioversion indications}}
 
{{Defibrillation and cardioversion indications}}
Line 7: Line 9:
  
 
==Equipment Needed==
 
==Equipment Needed==
*AED
+
*Automated External Defibrillator (AED)
 
*Defibrillator
 
*Defibrillator
  
Line 27: Line 29:
  
 
==Complications==
 
==Complications==
*Defibrillator Refractory VF
+
*Defibrillator Refractory [[VF]]
**Consider apply 2 defibrillators and delivering double sequential external shocks<ref>Hoch DH, et al. Double sequential external shocks for refractory ventricular fibrillation. J Am Coll Cardiol. 1994; 23(5):1141-5.</ref><ref>Cabanas JG, et al. Double Sequential External Defibrillation in Out-of-Hospital Refractory Ventricular Fibrillation: A Report of Ten Cases. Prehosp Emerg Care. 2015; 19(1):126-130.</ref>
+
**Consider apply 2 defibrillators and delivering [[Double simultaneous external defibrillation|double sequential external shocks]]<ref>Hoch DH, et al. Double sequential external shocks for refractory ventricular fibrillation. J Am Coll Cardiol. 1994; 23(5):1141-5.</ref><ref>Cabanas JG, et al. Double Sequential External Defibrillation in Out-of-Hospital Refractory Ventricular Fibrillation: A Report of Ten Cases. Prehosp Emerg Care. 2015; 19(1):126-130.</ref>
 
   
 
   
 
==See Also==
 
==See Also==
Line 38: Line 40:
  
 
==External Links==
 
==External Links==
 +
  
 
==References==
 
==References==
 
 
<references/>
 
<references/>
  
[[Category:Cards]]
+
[[Category:Cardiology]]
 
[[Category:Procedures]]
 
[[Category:Procedures]]
 +
[[Category:Critical Care]]

Latest revision as of 16:00, 9 October 2019

See critical care quick reference for defibrillation settings (joules) by weight.

Background

  • Unsynchronized shock

Indications

It is important to note that the procedure and indications differ between defibrillation and cardioversion

Defibrillation (Unsynchronized Cardioversion)

Synchronized Cardioversion

Contraindications

  • None

Equipment Needed

  • Automated External Defibrillator (AED)
  • Defibrillator

Procedure

  • Apply pads or paddles
    • Paddles may be slightly quicker but pads are viewed to be safer[1]
  • Larger pads reduce transthoracic impedance[2]
    • “Adult” size in adults
    • “Adult” size (8 to 10 cm) for children >10 kg (> approximately 1 year)[3]
    • “Infant” size for infants <10 kg
  • 4 accepted pad positions: anterolateral, anteroposterior, anterior-left infrascapular, and anterior-right-infrascapular
    • Anteroposterior position performs slightly better[4]
  • Biphasic setting
    • Initial 120-200J for VF/pulseless Vtach in adults (Monophasic 360J)[5]
    • Initial 2-4J/kg (Do not exceed J/kg) for pediatric VF/pulseless Vtach[6]

Complications

See Also

External Links

References

  1. Benedikte H, et al. Time and safety in defibrillation with paddles versus pads: A comparative study of two defibrillation regimes. Resuscitation. 2013; 84(11):e141–e142.
  2. Connell PN, et al. Transthoracic impedance to defibrillator discharge. Effect of electrode size and electrode-chest wall interface. J Electrocardiol. 1973; 6:313–M.
  3. Atkins DL, et al. Pediatric defibrillation: current flow is improved by using “adult” electrode paddles. Pediatrics. 1994; 94:90–93.
  4. Krasteva V, et al. Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation. Physiol Meas. 2006; 27:1009–1022.
  5. Neumar RW, et al. 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science. Part 8: Adult Advanced Cardiovascular Life Support. Circulation. 2010; 122: S729-S767.
  6. Kleinman ME, et al. 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science. Part 14: Pediatric Advanced Life Support. Circulation. 2010; 122: S876-S908.
  7. Hoch DH, et al. Double sequential external shocks for refractory ventricular fibrillation. J Am Coll Cardiol. 1994; 23(5):1141-5.
  8. Cabanas JG, et al. Double Sequential External Defibrillation in Out-of-Hospital Refractory Ventricular Fibrillation: A Report of Ten Cases. Prehosp Emerg Care. 2015; 19(1):126-130.