IVC ultrasound: Difference between revisions

(change order of categories)
 
(22 intermediate revisions by 6 users not shown)
Line 1: Line 1:
==Background==
==Background==
*Inferior vena cava measurement by ultrasound to estimate volume status
*Though controversial, IVC measurement by ultrasound can estimate volume status, fluid responsiveness, and fluid tolerance
*Measure both absolute diameter of IVC and percent collapse during inspiration of spontaneously breathing patients
**There is evidence to support that IVC diameter is consistently low in hypovolemia versus euvolemia<ref>Dipti A, et al. Role of inferior vena cava diameter in assessment of volume status: a meta-analysis. AJEM. 2012; 30:1414-1419.</ref>
*can use as a dynamic assessment after intervention (giving fluids)
**IVC change can estimate fluid responsiveness with sensitivity of 0.78 and specificity of 0.86<ref>Zhang Z, et al. Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis. Ultrasound Med Biol. 2014. May; 40(5):845-53.</ref>
*Unclear if applicable to intubated patients
*Can use as a dynamic assessment after intervention such as giving fluids or passive leg raise
*Dynamic changes is probably best measured in intubated patients
 
==Indications==
*Differentiate causes of shock
*Differentiate causes of shortness of breath
*Establish likelihood of fluid responsiveness
*Assess response to interventions


==Technique==
==Technique==
*Use curvilinear (abdominal) probe or phased array (cardiac) probe
#Select probe
*In subxyphoid cardiac view (epigastric), fan probe laterally to view the IVC draining into the right atrium
#*Curvilinear or phased array probe
**may start with subxyphoid view, place right atrium in center of screen and rotate probe 90 degrees clockwise to find IVC
#Location
*use M-mode to measure IVC collapse during inspiration
#*In subxyphoid cardiac view (epigastric), fan probe laterally to view the IVC draining and identify it draining into the right atrium
#*May start with subxyphoid view, place right atrium in center of screen and rotate probe 90 degrees clockwise to find IVC
#Longitudinal view
#*M-mode to measure IVC collapse during inspiration or estimation can be made in 2D with IVC in longitudinal axis
#*Measure both absolute diameter of IVC and percent collapse during inspiration of spontaneously breathing patients
#Dynamic measurements
#*Repeat measurements can be made after passive leg raise or IVF bolus


==Measurements==
==Findings==
{| cellspacing="1" cellpadding="1" border="1" style="width: 300px;"
{{Ultrasound findings for critically ill patients table}}
===Correlations Between IVC Size and CVP<ref>Goldflam K, et al. Focus on: Inferior vena cava ultrasound. ACEP News. June 2011.</ref>===
{| class="wikitable"
|-
|-
| '''IVC'''
! IVC (cm) !! Respiratory Change !! CVP (cm H2O)
| '''&nbsp;% Collapse during inspiration^'''
| '''CVP'''
|-
|-
| &lt;1.5cm
| <1.5 || Total collapse || 0-5
| &gt;50%
| 0-5
|-
|-
| 1.5-2.5cm
| 1.5-2.5 || >50% collapse || 6-10
| &gt;50%  
| 5-10
|-
|-
| 1.5-2.5cm
| 1.5-2.5 || <50% collapse || 11-15
| &lt;50%  
| 10-15
|-
|-
| &gt;2.5cm
| >2.5 || <50% collapse || 16-20
| Little phasicity
|-
| 15-20
| >2.5 || No change || >20
|}
|}
''Measure 2cm from IVC/RA junction or 1cm from IVC/hepatic vein junction''
==Images==
[[File:IVC.png|300px]]
==Pearls and Pitfalls==
*Aorta can be confused for IVC, ensure you visualize the vessel entering the atrium
*Ensure the vessel is viewed in full longitudinal axis as being off-center will give falsely narrow measurements
==Documentation==
===Normal Exam===
A bedside IVC ultrasound was performed to assess volume status in setting of dehydration. The IVC was identified in longitudinal access. The IVC was neither flat nor plethoric. There was less than 50% collapse with respirophasic measurements. This does not imply that the patient is not volume responsive but rather further testing is needed.
===Abnormal Exam===
A bedside IVC ultrasound was performed to assess volume status in setting of dehydration. The IVC was identified in longitudinal access. The IVC was flat with over 50% collapse with respirophasic measurements. There was evidence of volume depletion and fluid tolerance.


^Measure ~2cm from IVC/RA junction
A bedside IVC ultrasound was performed to assess volume status in setting of fluid overload. The IVC was identified in longitudinal access. The IVC was plethoric with less than 50% collapse with respirophasic measurements. There was evidence of volume overload.


*Can ask patient to sniff or valsalva to evaluate collapse
==Clips==
===Normal IVC===
<gallery>
File:Normal IVC.gif
File:Normal IVC 2.gif
</gallery>
===Flat IVC===
<gallery>
File:Flat IVC.gif
File:Flat IVC 2.gif
</gallery>


== See Also ==
===Plethoric IVC===
<gallery>
File:Plethoric IVC.gif
File:Plethoric IVC 2.gif
</gallery>
 
==Video==
{{#widget:YouTube|id= ci9W4MvyMHI}}
 
==External Links==
*[http://lifeinthefastlane.com/smacc-the-dark-art-of-ivc-ultrasound/ Life in the Fastlane - SMACC: The Dark Art of IVC Ultrasound]
*[https://www.acep.org/content.aspx?id=80791 ACEP Focus On: Inferior Vena Cava Ultrasound]
 
==See Also==
*[[Ultrasound (Main)]]
*[[Ultrasound (Main)]]


== References ==
==References==
Dawson, M. Mallin, M. Introduction To Bedside Ultrasound: Volumes 1 and 2.Emergency Ultrasound Solutions. 2012 Inkling File
<references/>
[[Category:Cards]] [[Category:Rads]]
 
[[Category:Ultrasound]]
[[Category:Radiology]]
[[Category:Cardiology]]

Latest revision as of 02:30, 30 August 2020

Background

  • Though controversial, IVC measurement by ultrasound can estimate volume status, fluid responsiveness, and fluid tolerance
    • There is evidence to support that IVC diameter is consistently low in hypovolemia versus euvolemia[1]
    • IVC change can estimate fluid responsiveness with sensitivity of 0.78 and specificity of 0.86[2]
  • Can use as a dynamic assessment after intervention such as giving fluids or passive leg raise
  • Dynamic changes is probably best measured in intubated patients

Indications

  • Differentiate causes of shock
  • Differentiate causes of shortness of breath
  • Establish likelihood of fluid responsiveness
  • Assess response to interventions

Technique

  1. Select probe
    • Curvilinear or phased array probe
  2. Location
    • In subxyphoid cardiac view (epigastric), fan probe laterally to view the IVC draining and identify it draining into the right atrium
    • May start with subxyphoid view, place right atrium in center of screen and rotate probe 90 degrees clockwise to find IVC
  3. Longitudinal view
    • M-mode to measure IVC collapse during inspiration or estimation can be made in 2D with IVC in longitudinal axis
    • Measure both absolute diameter of IVC and percent collapse during inspiration of spontaneously breathing patients
  4. Dynamic measurements
    • Repeat measurements can be made after passive leg raise or IVF bolus

Findings

Classic Ultrasound Findings For Critically Ill Patients

Disease IVC Cardiac Lung (Phased Array) Lung (Linear)
MI Focal WMA
Mod/Poor squeeze
NL or B-lines Sliding
Tamponade RA collapse with filling
RV collapse with filling
NL Sliding
PTX NL or Hyperdynamic Lung point
Consolidated lung
Absent lung sliding
Sepsis Hyperdynamic squeeze NL (see pneumonia) Sliding
Pneumonia NL or ↓ Hyperdynamic squeeze Unilateral B-lines Sliding
Decompensated HF Mod/Poor squeeze Bilateral B-lines Sliding
PE RV > LV
McConnell's sign
NL or Unilateral B-lines Sliding

Correlations Between IVC Size and CVP[3]

IVC (cm) Respiratory Change CVP (cm H2O)
<1.5 Total collapse 0-5
1.5-2.5 >50% collapse 6-10
1.5-2.5 <50% collapse 11-15
>2.5 <50% collapse 16-20
>2.5 No change >20

Measure 2cm from IVC/RA junction or 1cm from IVC/hepatic vein junction

Images

IVC.png

Pearls and Pitfalls

  • Aorta can be confused for IVC, ensure you visualize the vessel entering the atrium
  • Ensure the vessel is viewed in full longitudinal axis as being off-center will give falsely narrow measurements

Documentation

Normal Exam

A bedside IVC ultrasound was performed to assess volume status in setting of dehydration. The IVC was identified in longitudinal access. The IVC was neither flat nor plethoric. There was less than 50% collapse with respirophasic measurements. This does not imply that the patient is not volume responsive but rather further testing is needed.

Abnormal Exam

A bedside IVC ultrasound was performed to assess volume status in setting of dehydration. The IVC was identified in longitudinal access. The IVC was flat with over 50% collapse with respirophasic measurements. There was evidence of volume depletion and fluid tolerance.

A bedside IVC ultrasound was performed to assess volume status in setting of fluid overload. The IVC was identified in longitudinal access. The IVC was plethoric with less than 50% collapse with respirophasic measurements. There was evidence of volume overload.

Clips

Normal IVC

Flat IVC

Plethoric IVC

Video

{{#widget:YouTube|id= ci9W4MvyMHI}}

External Links

See Also

References

  1. Dipti A, et al. Role of inferior vena cava diameter in assessment of volume status: a meta-analysis. AJEM. 2012; 30:1414-1419.
  2. Zhang Z, et al. Ultrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis. Ultrasound Med Biol. 2014. May; 40(5):845-53.
  3. Goldflam K, et al. Focus on: Inferior vena cava ultrasound. ACEP News. June 2011.