Lung Protective Ventilator Settings[1]

  1. Mode
    • Volume-assist control
  2. Tidal Volume (lung protection)
    • Start 6-8cc/kg predicted body weight
      • Predicted/"ideal" body weight is used because a person's lung parenchyma does not increase in size as the person gains more weight.
    • Titrate down if peak pressure >30 mmHg
  3. Inspiratory Flow Rate (comfort)
    • More comfortable if higher rather than lower
    • Start at 60-80 LPM
  4. Respiratory Rate (titrate for ventilation)
    • Average patient on ventilator requires 120mL/kg/min for eucapnia
    • Start 16-18 breaths/min
    • Maintain pH = 7.30-7.45
  5. FiO2/PEEP (titrate for oxygenation)
    • Move in tandem to achieve:
    • SpO2 BETWEEN 88-95%
    • PaO2 BETWEEN 55-80
  6. The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000;342(18):1301-1308.