Initial ventilation settings

Disease Tidal Volume (mL/kg^) Respiratory Rate I:E PEEP FiO2
Normal lung 8 10-12 1:2 5 100%
Lung Protective (e.g. ARDS) 6 12-20 1:2 2-15 100%
Obstructive (e.g. bronchoconstriction) 6 5-8 1:4 5 100%
Hypovolemic 8 10-12 1:2 0-5 100%

^Ideal body weight