Hemothorax: Difference between revisions

(Text replacement - "*CXR" to "*CXR")
Line 12: Line 12:
**Supine - Fluid collections >1000cc can be missed
**Supine - Fluid collections >1000cc can be missed
**Mainstem bronchus intubation can appear like a hemothorax on CXR
**Mainstem bronchus intubation can appear like a hemothorax on CXR
*US
*[[lung ultrasound|US]]
*CT is gold standard
*CT is gold standard



Revision as of 16:06, 12 October 2019

Background

  • Each hemithorax can hold 40% of circulating blood volume

Clinical Features

Differential Diagnosis

Thoracic Trauma

Evaluation

  • CXR
    • Upright - Fluid collections >200-300cc can usually be seen
    • Supine - Fluid collections >1000cc can be missed
    • Mainstem bronchus intubation can appear like a hemothorax on CXR
  • US
  • CT is gold standard

Management

Adult Chest Tube Sizes

Chest Tube Size Type of Patient Underlying Causes
Small (8-14 Fr)
  • Alveolar-pleural fistulae (small air leak)
  • Iatrogenic air
Medium (20-28 Fr)
  • Trauma/bleeding (hemothorax/hemopneumothorax)
  • Bronchial-pleural fistulae (large air leak)
  • Malignant fluid
Large (36-40 Fr)
  • Thick pus

See Also